Specificaitons

  • Input Voltage Range: 10.5 – 60 Vdc depends on Inverter model.
  • Operating Temperature Range : 0 – 40 ℃
  • Storage Temperature Range : - 30 ℃ - 70 ℃
  • Stand-By Current Draw : < 40mA
  • Applicable Models : ASI series
  • Remote ON/OFF inverter operation
  • Ignition lockout information display and Return Override Function Acting

Introduction

● This is a simple ON / OFF remote control.
● The wire J1 is placed inside the remote controller and it is to indicate either Return Override
   Function or Ignition Lockout Function.
   *  J1 jumper “Open” – Return Override Function
   *  J1 jumper “Short” – Ignition Lockout Function
   Please note that the default mode is OPEN.
● The wire must go with a 12 Volt 0.5A fuse with proper sizes.
● Connect the wire RJ-11 to the remote port in rear of the panel.
   *  Ignition Lockout function – The Ignition lockout function is to turn the Inverter OFF when
         the auxiliary input wiring is connected to the ACC. (accessory), and 12 Volts is applied.
   *  Return Override Function – The Return Override Function is to turn the Inverter ON when
         the auxiliary input wiring is connected to the reverse gear Shift, and 12 Volts is applied.

LED Indicators

Dimensions

ARA-1 Remote Control Cables Drawing